• Gas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control System
  • Gas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control System
  • Gas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control System
  • Gas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control System
  • Gas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control System
  • Gas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control System

Gas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control System

After-sales Service: Installation and Debugging and Maintenance Support
Warranty: One Year Warranty, Lifetime Maintenance
Application: Mechanical Instrument, Electromagnetic Instrument, Flowmeters of Which Medium Is Air
Power: Electricity
Certification: CE
Voltage Output: 380V
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Current Output
40A
Thermocouple (TC)
S
Resistance-Temperature Detector (RTD)
Pt100(385)
LCD Display
With LCD Display
Customized
Customized
Transport Package
Wooden Case
Specification
DN15 to DN1200
Trademark
PB
Origin
China
HS Code
9031809090
Production Capacity
100

Product Description

Gas flow calibration equipment of DN15 to DN1200 atmospheric pressure sonic nozzle method and microcomputer automatic control system
 
Introduction:
 The system uses air as the medium, the critical flow venturi nozzle as the standard meter, and the flow meter is verified or tested by means of a vacuum pump to generate negative pressure in the system. The calibration diameter is DN15-DN200 (later can be extended to DN400), the test flow range is 1-7000m3/h (later can be extended to 10000m3/h), and the device expansion uncertainty is better than 0.3% (K=2)


Main technical parameters:
- Calibrated caliber size: DN15~DN1200
- Calibration method: sonic nozzle method
- Uncertainty of equipment expansion: master meter method  0.33%,0.5%
- Gas source pressure: 0.1MPa;
- Structural style: tiling


Main technical features:
- This calibration equipment is applied to the calibration of flowmeters of which medium is atmospheric pressure air;
- Sonic nozzle is adopted as the standard;

- Compact structure with high accuracy, repeatability and stability
- The nozzle structure is simple, sturdy and durable, of which a long calibration period (every 5 years).
- The equipment has a large calibration caliber to get a large calibration flow, and it's easy to install (pneumatic meter clamper) meters calibrated
- All stainless steel pipe, long service life
- Customers can freely choose the calibration time, calibration volume, flow points, calibration times, etc. of the flowmeters calibrated, which is very convenient for users to operate
-The software is easy to operate and has operating authority. Users can configure the content in the database according to the actual situation.
- Control and data acquisition adopt integrated design for microcomputer and lower machine, data can be transmitted remotely.

Gas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control System
Gas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control SystemGas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control SystemGas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control SystemGas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control System
Quality Control Process -
PB use ERP management system, which help plan and manage order information, from customer order to procurement, production, cost, inventory, distribution, transportation, finance. It universally helps to control and trace every process internally!
Gas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control System
Our Service- 
1. Setting trace file for every sold product, quarterly survey for every sold product.
2. Providing remote instruction and training for free.
3. Providing on-site services and repairs for free during warranty period

4. Spare parts and on-site service would be charged with best price after warranty period.
5. 7*24 hours online service for free, solution within 48 hours. 
6. If customer required, assigning experienced after-sales engineer for on-site service with 7 days. (Visa apply should be considered)


After Sales Support -
Warranty­­­­
The Guarantee/Warranty Period shall be a period of twelve months after on-site startup & commissioning or eighteen months after shipment, whichever occurs first. If any trouble or defect, originating with the design, material, and workmanship or operating characteristics of any Goods, arises at any time during GUARANTEE/WARRANTY period, PB shall, at his own expense and as promptly as possible, make such alterations, repairs and replacements.
On-Site Support
PB can do paid services of on-site startup, commissioning, installation supervision, training, by providing purchaser with the services of qualified English-speaking
engineer at step shall obtain all permits and l­­­­­icenses required to perform the services under this Agreement. 


FAQ:
 1. Are you a manufacturer or Trade Company?
    We are the R&D and manufacturer of calibration/testing system, founded in 2015, located in Shanghai Pudong district.

2. How to get a prompt quotation of a calibration/testing system?
  When you send the inquiry to us, please kindly send it with below information

  1) Object or medium of measurement
  2) Caliber size: DN_____
  3) Accuracy of measurement: _____%
  4) Rang of measurement

  5) Application


 3. What's the order process?
    a. Inquiry---provide us all clear requirements.
    b. Quotation---official quotation form with all clear specifications.

    c. Contract confirmation---provide correct contract details.
    d. Payment terms--- Negotiable.
    e. Production---mass production
    f. Shipping--- by sea, air or courier. Detailed picture of package will be provided.
    g. Installation and commissioning


4. What is the term of payment?
   T/T, L/C etc.


Other Related Products
Gas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control System

Factory image
Gas Flow Calibration Equipment of DN15 to DN1200 Atmospheric Pressure Sonic Nozzle Method and Microcomputer Automatic Control System

Thank you for reading and looking forward your further communication!  

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now