DN50 High Accuracy Coriolismaster Mass Flow Meter

Product Details
Customization: Available
After-sales Service: 1 Year to 2 Years
Warranty: 1 Year Warranty
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
to see all verified strength labels (18)
  • DN50 High Accuracy Coriolismaster Mass Flow Meter
  • DN50 High Accuracy Coriolismaster Mass Flow Meter
  • DN50 High Accuracy Coriolismaster Mass Flow Meter
  • DN50 High Accuracy Coriolismaster Mass Flow Meter
  • DN50 High Accuracy Coriolismaster Mass Flow Meter
  • DN50 High Accuracy Coriolismaster Mass Flow Meter
Find Similar Products
  • Overview
  • Company Profile
  • Product Description
  • Product Parameters
  • Applications
  • Customer Visit Our Factory
  • Our Customer
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
FCB-100
Accuracy
±0.2-0.5%
Main Application
Water, Wastewater, Nature Gas
Size
DN 15-DN200
Sensor
Tube/Flange
Application
Environmental Protection
Type
Coriolis Mass Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
JIS, DIN, ANS, GB, CE, RoHS, ISO
Name
Flow Meter
DN Size
DN 15- DN 200
Mass Flow
0.4 %
Denisty
0.01kg/L
Transport Package
Carton
Specification
DN 15 - DN 200
Trademark
Powderbuilder
Origin
Shanghai
HS Code
9026100000
Production Capacity
100000

Product Description

Company Profile

DN50 High Accuracy Coriolismaster Mass Flow Meter

DN50 High Accuracy Coriolismaster Mass Flow MeterWe have a strong engineering service team to service to global projects.
Include:   Software & Hardware updating, equipment installation & commissioning, Global sourcing, project localization.

Our Products include: 
Customized Automation Solution / Robotic
Calibration System & Instrumentation
ABBproducts Agent

CoriolisMaster FCB100, FCH100 
Coriolis mass flowmeter
DN50 High Accuracy Coriolismaster Mass Flow Meter

Product Description

Measurement made easy Compact device for high-precision measurement of mass and volume flow, density, temperature and concentration with just one device - The ideal transmitter for system integration •  Modbus for quick and comprehensive communication • Two fast digital outputs that can be configured as pulse outputs, frequency outputs or binary outputs •  Lower pressure loss, self-draining •  Global approvals for explosion protection •  MID / OIML approval for legal metrology - Integrated VeriMass device verification and diagnosis •  Predictive maintenance in the process •  Extended maintenance cycles •  Reduced maintenance effort - CoriolisMaster Software Tools •  DensiMass for concentration measurements, net mass and volume flow calculations •  FillMass for filling applications - CoriolisMaster FCH100 •  For hygienic applications

Product Parameters

Model number FCB1xx for standard applications                                              FCH1xx for hygienic applications
Process connections
Flange DIN 2501 / EN 1092-1 DN 10 to 200, PN 40 to 100                                             -
Flange ASME B16.5 DN ½ to 8in, CL150 to CL1500                                        -
JIS flange DN 10 to 200; JIS 10K to 20K                                           -
Pipe fitting DIN 11851 DN 10 to 100 (¼ to 4 in)                                                  DN 15 to 100 (½ to 4 in)
Pipe fitting SMS 1145 DN 25 to 80 (1 to 3 in)                                                  -
Tri-clamp DIN 32676 (ISO 2852)
Tri-clamp BPE
DN 15 to 100 (¼ to 4 in)
DN ⅜ to 4 in
DN 20 to 100 (¼ to 4 in)
DN ⅜ to 4 in
Female thread DIN ISO 228 and
ASME B 1.20.1
DN 15; PN 100                                                             -
Other connections On request                                                                    On request
Wetted material Stainless steel 1.4435 or 1.4404 (AISI 316L), nickel-alloy Stainless steel, polished 1.4404 (AISI 316L) or 1.4435 C4 / C22                                                                     (AISI 316L)
Approvals and certificates
Explosion protection
ATEX, IECEx, UKEX, EAC-Ex
Zone 0, 1, 2, 21, 22                                                        Zone 0, 1, 2, 21, 22
Explosion protection conforming to cFMus Class I Div. 1, Class I Div. 2, Zone 0, 1, 2, 21                     Class I Div. 1, Class I Div. 2, Zone 0, 1, 2, 21
Hygiene approvals -                                                                               FDA compliant
Legal metrology OIML R117, MID, devices for legal metrology in accordance with API / AGA
… Overview - models
 Device description
 
Model number FCB130                                           FCB150 FCH130 FCH150
Measuring accuracy for liquids
Mass flow* 0.4 %, 0.25 % and 0.2 %         0.1 % and 0.15 % 0.4 %, 0.25 % and 0.2 % 0.1 % and 0.15 %
Volume flow* 0.4 %, 0.25 % and 0.2 %        0.15 % and ±0.11 % 0.4 %, 0.25 % and 0.2 % 0.15 % and ±0.11 %
Density 0.01 kg/l                                              0.002 kg/l
     0.001 kg/l (optional)
     0.0005 kg/l
0.01 kg/l      0.002 kg/l
     0.001 kg/l (optional)
     0.0005 kg/l
Temperature 1 K                                                      0,5 K 1 K 0,5 K
Measuring accuracy for gases* 1 %                                                     0,5 % 1 % 0,5 %
Permissible measuring medium −50 to 160 °C                            −50 to 205 °C −50 to 160 °C −50 to 205 °C
temperature (−58 to 320 °F)                          (−58 to 400 °F) (−58 to 320 °F) (−58 to 400 °F)
Permissible ambient temperature −40 to 70 °C (-40 to 158 °F)    
Power supply 11 to 30 V DC, nominal voltage: 24 V DC    
IP rating in accordance with EN 60529 IP 65 / IP 67 / IP 68 (immersion depth: 5 m), NEMA 4X    
Communication Modbus® RTU, RS485    
Outputs in serial production       Digital output 1: passive
      Digital output 2: passive
   
External output zero return Yes    
External totalizer reset Yes    
Flow measurement in forward flow and reverse flow direction Yes    
Empty pipe detection Yes, based on preconfigured density alarm    
Self-monitoring and diagnosis Yes    
Field optimization for flow and density Yes    
Concentration measurement 'DensiMass' Yes, optional on models FCB150 and FCH150    
'FillMass' filling function Yes, optional on models FCB150 and FCH150    
"VeriMass" diagnosis function Yes, optional    
*     Indication of accuracy in % of the measured value (% of meas.val.)

General data
Device description
The CoriolisMaster FCB100, FCH100 is the low-cost and
simple ABB mass flowmeter with the new DSP transmitter.
The device is equipped with a Modbus® interface and two
fast digital outputs that can be configured as pulse,
frequency or binary outputs.
The CoriolisMaster FCB100, FCH100 operates in accordance
with the Coriolis principle. The design offers the following
benefits:
      Space-saving, robust design.
•     Variety of process connections.
      Two digital outputs.
      Communication viaModbus® RTU protocol.
•      Ex approval The user can select the "i" or "e" type of
protection for the output circuits; the type chosen will depend on the circuits which are connected. The type   of protection can be changed even after installation      has been completed.

… General data 
FillMass batch function
Only for FCB150 / FCH150
DN50 High Accuracy Coriolismaster Mass Flow Meter   Supply tank 2   Sensor 3 Start / stop fill operation (Modbus) 4  Fill valve 5   Filling tank Figure 2:    FillMass fill function Start    Start of the filling operation via Modbus DO    State of the digital output for the fill valve Q    Flow rate VO Valve open (filling started) VC Valve closed (fill quantity reached) t1    Valve closing time t2    Overrun time The integrated FillMass fill function allows filling operations with filling times of > 3 s. For this purpose, the filling quantity is given via an adjustable totalizer. The Modbus interface is used to configure and control the fill function. The valve is triggered via one of the digital outputs and closed again once the preset filling quantity is reached. The transmitter measures the overrun quantity and calculates the overrun correction from this. Additionally, the low flow cut-off can be activated if required. Concentration measurement DensiMass Only for FCB150 / FCH150 The transmitter can calculate the current concentration from the measured density and temperature using concentration   matrices. The following concentration matrices are preconfigured in the transmitter as standard: •      Concentration of sodium hydroxide in water •      Concentration of alcohol in water •      Concentration of sugar in water •      Concentration of maize starch in water •      Concentration of wheat starch in water •      Concentration of antifreeze in water In addition, the user can enter two user-defined matrices: •      Up to 100 values with one matrix •      Up to 50 values per matrix with two matrices Calculating standard volumes and standard densities of liquids If a suitable matrix is available, the DensiMass function also    allows the measured volume to be corrected for any selected temperature. The measured density can also be corrected for a given temperature. However, this is only possible when measuring liquids and after entering an appropriate matrix. This correction can also be performed using the default matrices (see above).
The calculated standard volumes and standard densities can also be issued for all other process variables.
The software 'DensiMatrix' is available for the easy input of the matrix.

Accuracy of the concentration measurement
The accuracy of the concentration measurement is
determined in the first instance by the quality of the matrix data entered.
However, as the calculation is based on temperature and density (the input variables), the accuracy of the
concentration measurement is ultimately determined by the measuring accuracy of the temperature and the density.

Example:
Density of 0 % alcohol in water at 20 °C (68 °F): 998.23 g/l      Density of 100 % alcohol in water at 20 °C (68 °F): 789.30 g/l
 
Concentration Density
100 % 208.93 g/l
0.48 % 1 g/l
0.96 % 2 g/l
0.24 % 0.5 g/l
Thus, the accuracy class of the density measurement directly determines the accuracy of the concentration measurement.
… General data
Enhanced Coriolis Control (ECC)function
The Enhanced Coriolis Control (ECC)function has been
specially developed for demanding applications, such as:
      Liquids with gas phase
      Liquids with rapidly changing densities
      Fill operations with surge phases at the beginning or end
      Liquids with high viscosity
After the ECC function is activated, the device applies a
particularly quick control algorithm to control the oscillating  tubes in the device and therefore provide significantly better behavior in the applications listed above.
In addition, the ECC function offers a special noise
suppression filter for mass flow measurement and density measurement.
In the case of particularly demanding applications,
disruptions can thus be actively filtered and the
measurement can be implemented in a considerably more stable manner.
For the filters, a variety of time constants between 0.5 s and 8 s can be selected.
Since Coriolis mass flowmeters measure the mass flow and
density separately, the CoriolisMaster features a separate filter each for mass flow measurement and density
measurement.

Devices for legal metrology in accordance with MID / OIML R117
The Coriolis mass flowmeters CoriolisMaster FCBx50 are type-tested for legal metrology in accordance with
MID / OIML R117 in accuracy classes 0.5 and 0.3.
Additional information can be found on the corresponding
certificate. 
When ordering, select one of the optional order codes:
•     CT4 - Approved for official calibration in accordance with MID (OIMLR117 Cl0.5)
•     CT3 - Approved for official calibration in accordance with MID (OIMLR117 Cl0.5/0.3)
All Coriolis mass flowmeters FCBx50 for legal metrology
receive a 3-point flow rate calibration at the factory, which   demonstrates measuring accuracy in accordance with the    OIML-R117-2019 guidelines at minimum (Qmin), medium and maximum (Qmax) flow rates.
 
Nominal
diameter
Q1 (tol. +10 %) [kg/h] Q2 (tol. ±10 %) [kg/h] Q3 (tol. −20 %) [kg/h]
DN 15 365 2489 6500
DN 25 1620 10570 27000
DN 50 4550 27335 67000
DN 80 14500 91489 145000
DN 100 23000 124597 290000
DN 150 32000 178053 290000*
*     corresponds to approx. 60 % QmaxCT
Note
Use in accordance with API / AGAstandards is also possible.
Please observe the additional remarks in the operating and commissioning instruction.
 
Applications in accordance with API
(American Petroleum Institute)
For applications in accordance with API Chapter 5.6, the
CoriolisMaster FCB100, FCH100 provides special parameters:
•     Calibration Pressure: Measuring medium pressure at which the device was calibrated at ABB.
•     Calibration Temp.: Measuring medium temperature at which the device was calibrated at ABB.
      Pressure Level: Parameters for entry of the current operating pressure in the device by the user.
•     Flow Compens. factor: Display / output of the current compensation factor for mass flow calculation.
•     Density Comp. factor: Display / output of the current compensation factor for density calculation.
      P.Comp.Status (PECI): In accordance with API, the user can set the following states:
-     1: CT: Compensation in the Coriolis flowmeter based on the current pressure entered in the   ' Pressure Level' parameter.
-     2: TD: Compensation in the Coriolis flowmeter switched off - compensation is performed
externally (Tertiary Device)
-     3: OS: Compensation in the Coriolis flowmeter
switched off - compensation is not performed on site (Off Site)
-     4: NA: Compensation in the Coriolis flowmeter
switched off - compensation is not deemed to be necessary, since the device is operating at a
pressure for which the device has been proved.

VeriMass erosion monitor
The integrated diagnosis function VeriMass allows the status of the meter tube to be monitored. This enables changes due to material erosion and the formation of deposits on the
meter tube walls to be identified at an early stage.
If the set limit value is exceeded, an alarm is triggered, for example via the programmable digital output or HART,
depending on the configuration.
The limit value for the erosion monitor can be set either automatically or manually.
Automatic adjustment
The transmitter monitors the sensor's driver current over a   prolonged period and creates a 'fingerprint' for the relevant application. The transmitter generates a corresponding
tolerance value for deviations in the driver current.
The transmitter compares the behavior of the driver current    with the generated fingerprint and triggers the relevant error message in the event of prolonged deviations.
Manual adjustment
For applications where automatic adjustment of the erosion monitor does not provide a satisfactory result, the erosion    monitor can be adjusted manually.
For more information, please contact ABB Service or the sales organization.
-
Flowmeter sensor
General installation conditions
Installation location and assembly
Note the following points when selecting the installation location and when mounting the sensor:
•     The ambient conditions (IP rating, ambient
temperature range T ambient) of the device must be adhered to at the installation location.
•     Sensors and transmitters must not be exposed to
direct sunlight. If necessary, provide a suitable means of sun protection on site. The limit values for ambient temperature T ambient  must be adhered to.
•     On flange devices, ensure that the counterflanges of     the piping are aligned plane parallel. Only install flange devices with suitable gaskets.
      Prevent the sensor from coming into contact with other objects.
•     The device is designed for industrial applications.     No special EMC protective measures are required if  the electromagnetic fields and interference at the     installation location of the device comply with 'Best Practice' (in accordance with the standards listed in the declaration of conformity).
Maintain a suitable distance from electromagnetic     fields and interference that extend beyond the usual dimensions.

Seals
Users are responsible for selecting and mounting suitable gaskets (material, shape).
Note the following points when selecting and mounting gaskets:
•     Use gaskets made from a material that is compatible with the measuring medium and measuring medium  temperature.
•     Gaskets must not extend into the flow area, since
possible turbulence may influence the accuracy of the device.
Calculating pressure loss
Pressure loss depends on the properties of the medium and the flow rate.

Applications

DN50 High Accuracy Coriolismaster Mass Flow Meter
DN50 High Accuracy Coriolismaster Mass Flow Meter

Customer Visit Our Factory

DN50 High Accuracy Coriolismaster Mass Flow Meter

Our Customer

DN50 High Accuracy Coriolismaster Mass Flow MeterDN50 High Accuracy Coriolismaster Mass Flow MeterDN50 High Accuracy Coriolismaster Mass Flow Meter

Certifications

DN50 High Accuracy Coriolismaster Mass Flow MeterDN50 High Accuracy Coriolismaster Mass Flow Meter

FAQ

1.Q: How long is the delivery?
-- Mostly within 10days

2.Q:Can I get a sample?
-- Sure, contact our sales please

 
3.Q:What is your MOQ?
-- 1pcs

 
4.Q: How about warranty time?
-- 12-18months

 
5.Q: How can I visit your factory?
-- Fly to Shanghai air port, it's our pleasure to pick you up.

 
6.Q:How do you control your quality ?
-- We have ERP system .we control from parts, process, testing, packing ,retesting.
 
7.Q: Do you have test report for each product?
-- Yes,we have test report for each product.
 
8.Q: Can you customize product for us according to our required specifications?
-- Yes,we are OEM manufacturer,we could customize products according to your required specifications.
 
Every Flowmeter with sensor will be tested two times before reach you, after that sport test for the third time. Make sure about the quantity.Welcome to order our products

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier