Structure Design: | Flange Type |
---|---|
Pressure Range: | High Pressure |
Customized: | Non-Customized |
The LLT100 is a high performance laser transmitter that accurately measures level, distance and position over short and long ranges. It is a non-contact, level measuring instrument designed for industrial applications and harsh environments.
The LLT100 is specifically made for industrial applications and harsh environments. It provides continuous, non-contact level measurement capabilities for process automation and inventory management in industries such as mining, aggregates, oil and gas, chemicals, food and beverages, power, pulp and paper, pharma, and water and waste water.
Low cost of ownership
- No maintenance
- No calibration necessary
- Versatile level transmitter
Reliable
- Precise measurement of any solid or liquid surface
- Dust and fog penetration capabilities
- Explosion proof class 1 / division 1 (zone 1)
Convenient
- Fast and flexible installation
- Easy setup function
- 2 wire powered and HART communication
Fast delivery
- Less than 2 weeks from order to reception
Accessories
Dust tube
- Avoids dirt or splashing liquids on the window
Cooling tube
- Increases max. process temperature to 280°C/535°F
Heated window
- Prevents condensation on window (requires 4 wire power)
Integral Through-the-Glass user interface
- Configuration directly on the unit
Rotating bracket
- Ideal for aiming the LLT100 laser beam
Swivel flange
- Provides precise aiming of the LLT100 laser beam. Especially useful in liquid applications
Laser pointer tool
- Used to provide a visual reference when aligning LLT100
Process flanges
Universal flange (aluminum or stainless steel)
- Flange bolt pattern fits both 2 in. ASME150 and DN50 PN 16
- Maximum pressure: 2 bar (29 psi)
- Hazarous area class 1 / division 1 (zone 1)
High pressure
- 2 in. class 150 flange
- 2 in. class 300 flange
- DN50 PN16 flange
- DN50 PN40 flange
- Hazardous area class 1 / division 1 (zone 1)
- Can be used to form a barrier to zone 0
Hygienic interface
- 4 in. triclover clamp
Measurement
Range
0.5 to 30 m (2 to 100 ft) for liquids
0.5 to 100 m (2 to 330 ft) for solids
0.5 m to 200 m (2 ft to 660 ft) for positioning applications with reflective target
Resolution
5 mm (0.2 in)
Typical accuracy
±11 mm (0.4 in)
Measuring beam
Laser wave length: 905 nm, eye safe, Class 1
Laser beam divergence
< 0.35°
Environmental conditions
Operating temperature
-40° to +60°C (-40 to +140°F), up to 280°C (535°F) with cooling tube
Storage temperature
-40 to +85°C (-40 to +185°F)
Survival temperature
-40°C to +80°C (-40°F to +175°F)
Process pressure
- Base model: -1 to +2 bar (29 psi)
- Hygienic model: -1 to +1 bar (15 psi)
- Pressure-rated model: -1 to +49.6 bar (719 psi), depending on flange
Output
Power supply
Mechanical
Operation