• Vortexmaster Fsv430
  • Vortexmaster Fsv430
  • Vortexmaster Fsv430
  • Vortexmaster Fsv430
  • Vortexmaster Fsv430
  • Vortexmaster Fsv430

Vortexmaster Fsv430

After-sales Service: Installation and Debugging
Warranty: 1 or 2 Years
Accuracy: ±0.2-0.5%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas, Gas
Type: Thermal Mass Flowmeters
Measuring Media: Gas
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
FSV430
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
DIN, ANS, GB, CE
Trademark
ABB
Origin
China
Production Capacity
500000

Product Description

VortexMaster FSV430
 
The new generation of vortex flowmeters
Maintenance-free, high-tech vortex flowmeter for your process
The robust VortexMaster flowmeters provide reliable measurements of liquid, gas and steam and are available in flange-mount and wafer-type designs. • Digital signal processing for volume measurement and volume totalizing with analog and digital outputs • Mass/energy flow or standard flow measurement without additional flow computer • Up to 4 internal totalizers for highest transparency depending on the operation mode • SensorMemory for easy replacement of components or entire transmitters for remote devices • Removable display unit for simple parameterization • Integrated 4 to 20 mA and/or HART input for external pressure, temperature, density or concentration information • Available with 4 to 20 mA output with HART 7 or Modbus RTU communication • Global approvals for explosion protection
Vortexmaster Fsv430Vortexmaster Fsv430Vortexmaster Fsv430

Vortexmaster Fsv430


Vortexmaster Fsv430



Vortexmaster Fsv430Vortexmaster Fsv430

Product
Description Category (hide all) (show all)
FMT200 OEM oriented industrial meter setup for precise and dynamic process gas mass flow measurement in standard and advanced application
Flow Measurement Products»Thermal Mass Flowmeters
FMT400 Versatile Industrial meter setup for precise and dynamic process gas mass flow measurement in standard and advanced application
Flow Measurement Products»Thermal Mass Flowmeters
FMT200-D Basic meter setup for compressed air, nitrogen, leakage detection or biogas.
Flow Measurement Products»Thermal Mass Flowmeters
FMT200-ECO2 Compact, dynamic and universal meter setup for OEM solutions or other stationary dosing equipment.
Flow Measurement Products»Thermal Mass Flowmeters
FMT400-VTS Compact designed standard meter setup for sensitive process gas mass flow measurement. Hygienic version available as -VTCS.
Flow Measurement Products»Thermal Mass Flowmeters
FMT500-IG Universal designed advanced meter setup for sensitive, multivariable process gas mass flow measurement.
Flow Measurement Products»Thermal Mass Flowmeters
FMT700-P Reference class thermal mass flowmeter for test benches.
Flow Measurement Products»Thermal Mass Flowmeters
 
1 .
 
Thermal mass flowmeter
SensyMaster FMT200

The SensyMaster FMT230 offers a high quality and cost effective solution for precise and dynamic direct mass flow measurements of gases in low and medium pressure conditions. The model comes preconfigured for the application, ready to be installed by OEM customers.
The FMT250 adds high accuracy and extended functionality for advanced applications.
SensyMaster's concept comprises high grade thermal sensor elements with superior long-term stability, the ABB platform based electronics with comprehensive signal evaluation capabilities for a high degree of performance and reliability. The software offers the ApplicationSelector that allows to change application parameters and create new applications on site and VeriMass the fingerprint based thermal sensor element verification function.
Both models communicate via MODBUS Interface and follow the SmartSensor concept.
The SensyMaster FMT230 is ideally suited for all OEM applications, the FMT250 for advanced OEM application. 

Overview
Precise and dynamic direct mass flow measurement of gases for OEM applications.
High-grade thermal sensor elements
- superior long-term stability
- effective sensor element protection frame with flow conditioning properties
SmartSensor solution
- Meter intelligence located at the sensor
- all digital solution
- reduced wiring costs with industry standard connection cables
- long cable distances are possible
SensorApplicationMemory
- Plug and play electronics replacement
- Redundant data storage for maximum data security
ABB common electronic concept
- MODBUS communication interface
- Multiple 32-bit processor structure
- full digital heating circuit control
- dynamic temperature compensation
ApplicationSelector
- Adaption of the characteristic application parameters on site
- choice between up to two applications (FMT230)
- choice between up to eight applications (FMT250)
- setup new applications without the need for recalibration (FMT250)
VeriMass onboard verification and diagnostics
- Fingerprint based SensorCheck to verify the integrity of the thermal sensor elements
- continuous health check of the meter
- parameter plausibility check

SensyMaster FMT200---Data
General specifications:
Measuring media
- Air, Nitrogen, Oxygen, Carbon dioxide, Methane, Hydrogen, Natural Gas, Biogas, Helium, Argon, Propane, Ethane, Ethene, Butane, Ammonia, more gas types on request
FMT230 measuring accuracy for air under reference conditions
- ±1.2 % of rate within 10 … 100 % of measuring range
- ±0.12 % full scale within 1 … 10 % of the measuring range
FMT250 measuring accuracy for air under reference conditions
- ±0.6 % of rate ±0.05 % full scale
FMT250 measuring accuracy for gases under reference conditions
- with optional process gas calibration 
- ±1.6 % of rate ±0.1 % full scale
Integral mount transmitter design
- single compartment transmitter housing
Measuring medium temperature
- -25 … 150 °C (-13 … 302 °F)
Ambient temperature
- -20 … 70°C ( -4 … 158°F)
- optional -40 … 70 °C (-40 … 158 °F)
- optional -50 … 70 °C (-58 … 158 °F)
Supply Voltage
- 24 V DC ±20 %
Process adaption via pipe components in different designs
- partial measuring sections (DN 25 …DN 100)
- wafer design pipe components (DN 40 … DN 200)
- Weld-on adapters (DN 100 … DN 3000)
FMT250 added functionality
- high accuracy calibration
- process gas calibration 
- extended Measuring range 
- high medium temperature up to 300 °C (572 °F) 
- filling application software
- ApplicationSelector with up to 8 applications
   …with up to 4 customer set applications
   …with selectable gas type
   …with selectable pipe inner diameter

Vortexmaster Fsv430

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now