• Master Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted Remotely
  • Master Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted Remotely
  • Master Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted Remotely
  • Master Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted Remotely
  • Master Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted Remotely
  • Master Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted Remotely

Master Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted Remotely

After-sales Service: If Voice or Video Support Cannot Be Solved, Send E
Warranty: Warranty of One Year and Lifelong Maintenance
Application: Mechanical Instrument, Electromagnetic Instrument, Heat Meters
Power: Electricity
Certification: CE
Voltage Output: 380V
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Introduction
  • Main technical parameters
  • Main technical features
  • Quality Control Process
  • Our Service
  • After Sales Support
  • Other Related Products
  • Factory image
Overview

Basic Info.

Current Output
40A
Thermocouple (TC)
S
Resistance-Temperature Detector (RTD)
Pt100(385)
LCD Display
With LCD Display
Customized
Customized
Transport Package
Wooden Case
Specification
DN65-DN400
Trademark
PB
Origin
China
HS Code
9031809090
Production Capacity
1000

Product Description

Liquid flow Calibration equipment system

Introduction

Master meter method, mass method calibration equipment for big caliber (DN65-DN400)heat meters and microcomput control system

Main technical parameters


- Calibrated caliber size: DN65~DN400
- Calibration method: master meter method, mass method
- Uncertainty of equipment expansion: master meter method0.25%,0.5%;mass method 0.05%,0.1%
-temperature range:4~95ºC/normal~95ºC;special reqest reaches≤130ºC;

- Structural style:tiling

 

Main technical features


- This calibration equipment for liquid flow is applied to various big caliber  heat meters of which medium is hot water
- system design pressure reaches 0.5Mpa

- control and data acquisition adopt integrated design for microcomputer and lower machine, data can be transmitted remotely
Master Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted RemotelyMaster Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted Remotely


Master Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted RemotelyMaster Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted Remotely

 

Quality Control Process

PB use ERP management system, which help plan and manage order information, from customer order to procurement, production, cost, inventory, distribution, transportation, finance. It universally helps to control and trace every process internally!

Master Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted Remotely
 

Our Service


1. Setting trace file for every sold product, quarterly survey for every sold product.
2. Providing remote instruction and training for free.
3. Providing on-site services and repairs for free during warranty period

4. Spare parts and on-site service would be charged with best price after warranty period.
5. 7*24 hours online service for free, solution within 48 hours. 
6. If customer required, assigning experienced after-sales engineer for on-site service with 7 days. (Visa apply should be considered)

 

After Sales Support


Warranty­­­­
The Guarantee/Warranty Period shall be a period of twelve months after on-site startup & commissioning or eighteen months after shipment, whichever occurs first. If any trouble or defect, originating with the design, material, and workmanship or operating characteristics of any Goods, arises at any time during GUARANTEE/WARRANTY period, PB shall, at his own expense and as promptly as possible, make such alterations, repairs and replacements.
On-Site Support
PB can do paid services of on-site startup, commissioning, installation supervision, training, by providing purchaser with the services of qualified English-speaking
engineer at step shall obtain all permits and l­­­­­icenses required to perform the services under this Agreement. 

 

Other Related Products

Master Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted Remotely

 

Factory image

 

Master Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted RemotelyOur customers
Master Meter Method, Mass Method Calibration Equipment of Liquid Flow Meter with Data to Be Transmitted Remotely
FAQ

1. Are you a manufacturer or Trade Company?

    We are the R&D and manufacturer of calibration/testing system, founded in 2015, located in Shanghai Pudong district.

2. How to get a prompt quotation of a calibration/testing system?
  When you send the inquiry to us, please kindly send it with below information

  1) Object or medium of measurement
  2) Caliber size: DN_____
  3) Accuracy of measurement: _____%
  4) Rang of measurement

  5) Application

 3. What's the order process?
    a. Inquiry---provide us all clear requirements.
    b. Quotation---official quotation form with all clear specifications.

    c. Contract confirmation---provide correct contract details.
    d. Payment terms--- Negotiable.
    e. Production---mass production
    f. Shipping--- by sea, air or courier. Detailed picture of package will be provided.
    g. Installation and commissioning


4. What is the term of payment?
   T/T, L/C etc.


Thank you for reading and looking forward your further communication!  


 